Jump to content



EVS

Air flow scheme
Performance ranges
  • Unit coolers capacity: from 0,25 to 1,70 kW *
  • Brine coolers and CO2 coolers: customized on demand
  • Airflow: from 260 to 930 m3/h
Coil features
  • High heat exchange efficiency
  • Designed with special profile aluminium fins and copper tubes
  • Dual fin spacing: 3,5 / 7,0 mm in EVS standard; 4,5 / 9,0 in the EVS/B version
Standard defrost Electric (ED) 230V/1/50Hz
Casing features Made of a magnesium aluminium alloy, with a smooth finish covered by a plastic protection film
Fan motor features
  • Diameter: 200 mm
  • Single-phase
  • Voltage: 230V/50-60Hz
  • Protection grade: IP 42
  • Class of insulation: B
  • Inner thermal contact protection
  • Working temperature: from -35 °C to +40 °C
Fan guard features Manufactured in fibreglass charged polyamide, according to EN 294 standards
Testing Heat exchangers are supplied clean and tested at a pressure of 30 bars
Miscellaneous The EVS/B models are provided with an inner drip tray and a terminal box, with IP 54 protection grade, for the connections of fan motors and electric heaters
* Nominal capacity: assessed in practical operating ambient, i.e. wet conditions; refrigerant R404A; air inlet temperature = 0 °C; evap. temperature = -8 °C; ΔT = 8 K.